Skip to Main content Skip to Navigation
Journal articles

Improving Axial Resolution in Confocal Microscopy with New High Refractive Index Mounting Media

Abstract : Resolution, high signal intensity and elevated signal to noise ratio (SNR) are key issues for biologists who aim at studying the localisation of biological structures at the cellular and sub-cellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF), a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK) with a re-fractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.
Document type :
Journal articles
Complete list of metadata

Cited literature [27 references]  Display  Hide  Download

https://hal.sorbonne-universite.fr/hal-01233480
Contributor : Gestionnaire Hal-Upmc Connect in order to contact the contributor
Submitted on : Wednesday, November 25, 2015 - 11:46:36 AM
Last modification on : Thursday, December 10, 2020 - 12:30:26 PM
Long-term archiving on: : Saturday, April 29, 2017 - 3:13:32 AM

File

journal.pone.0121096.pdf
Publication funded by an institution

Licence


Distributed under a Creative Commons Attribution 4.0 International License

Identifiers

Citation

Coralie Fouquet, Jean-François Gilles, Nicolas Heck, Marc dos Santos, Richard Schwartzmann, et al.. Improving Axial Resolution in Confocal Microscopy with New High Refractive Index Mounting Media. PLoS ONE, Public Library of Science, 2015, 10 (3), pp.e0121096. ⟨10.1371/journal.pone.0121096⟩. ⟨hal-01233480⟩

Share

Metrics

Record views

1111

Files downloads

474