R. D. Burgoyne and A. Morgan, Secretory Granule Exocytosis, Physiological Reviews, vol.83, issue.2, pp.581-632, 2003.
DOI : 10.1152/physrev.00031.2002

URL : https://hal.archives-ouvertes.fr/hal-00478869

J. D. Keighron, A. G. Ewing, and A. S. Cans, Analytical tools to monitor exocytosis: a focus on new fluorescent probes and methods, The Analyst, vol.132, issue.4, pp.1755-1763, 2012.
DOI : 10.1039/c2an15901e

S. Ge, S. Koseoglu, and C. L. Haynes, Bioanalytical tools for single-cell study of exocytosis, Analytical and Bioanalytical Chemistry, vol.5, issue.8, pp.3281-3304, 2010.
DOI : 10.1007/s00216-010-3843-0

R. Borges, M. Camacho, and K. D. Gillis, Measuring secretion in chromaffin cells using electrophysiological and electrochemical methods, Acta Physiologica, vol.84, issue.2, pp.173-184, 2008.
DOI : 10.1111/j.1748-1716.2007.01814.x

M. Lindau, High resolution electrophysiological techniques for the study of calcium-activated exocytosis, Biochimica et Biophysica Acta (BBA) - General Subjects, vol.1820, issue.8, pp.1234-1242, 2012.
DOI : 10.1016/j.bbagen.2011.12.011

C. Amatore, S. Arbault, M. Guille, and F. Lemaitre, Electrochemical Monitoring of Single Cell Secretion: Vesicular Exocytosis and Oxidative Stress, Chemical Reviews, vol.108, issue.7, pp.2585-2621, 2008.
DOI : 10.1021/cr068062g

H. F. Cui, J. S. Ye, Y. Chen, S. C. Chong, X. Liu et al., In situ temporal detection of dopamine exocytosis from l-dopa-incubated MN9D cells using microelectrode array-integrated biochip, Sensors and Actuators B: Chemical, vol.115, issue.2, pp.634-641, 2006.
DOI : 10.1016/j.snb.2005.10.042

H. Cui, J. Ye, Y. Chen, S. Chong, and F. Sheu, Microelectrode Array Biochip:?? Tool for In Vitro Drug Screening Based on the Detection of a Drug Effect on Dopamine Release from PC12 Cells, Analytical Chemistry, vol.78, issue.18, pp.6347-6355, 2006.
DOI : 10.1021/ac060018d

M. Chuang, H. Lai, J. A. Ho, and Y. Chen, Multifunctional microelectrode array (mMEA) chip for neural-electrical and neural-chemical interfaces: Characterization of comb interdigitated electrode towards dopamine detection, Biosensors and Bioelectronics, vol.41, pp.602-607, 2013.
DOI : 10.1016/j.bios.2012.09.030

A. Yakushenko, J. Schnitker, and B. Wolfrum, Printed Carbon Microelectrodes for Electrochemical Detection of Single Vesicle Release from PC12 Cells, Analytical Chemistry, vol.84, issue.10, pp.4613-4617, 2012.
DOI : 10.1021/ac300460s

Y. F. Gao, X. H. Chen, S. Gupta, K. D. Gillis, and S. Gangopadhyay, Magnetron sputtered diamond-like carbon microelectrodes for on-chip measurement of quantal catecholamine release from cells, Biomedical Microdevices, vol.14, issue.5, pp.623-629, 2008.
DOI : 10.1007/s10544-008-9173-8

Y. F. Gao, S. Bhattacharya, X. H. Chen, S. Barizuddin, S. Gangopadhyay et al., A microfluidic cell trap device for automated measurement of quantal catecholamine release from cells, Lab on a Chip, vol.12, issue.23, pp.3442-3446, 2009.
DOI : 10.1039/b913216c

I. A. Ges, K. P. Currie, and F. Baudenbacher, Electrochemical detection of catecholamine release using planar iridium oxide electrodes in nanoliter microfluidic cell culture volumes, Biosensors and Bioelectronics, vol.34, issue.1, pp.30-36, 2012.
DOI : 10.1016/j.bios.2011.11.050

I. A. Ges, R. L. Brindley, K. P. Currie, and F. J. Baudenbacher, A microfluidic platform for chemical stimulation and real time analysis of catecholamine secretion from neuroendocrine cells, Lab on a Chip, vol.25, issue.23, pp.4663-4673, 2013.
DOI : 10.1039/c3lc50779c

G. M. Dittami and R. D. Rabbitt, Electrically evoking and electrochemically resolving quantal release on a microchip, Lab Chip, vol.22, issue.1, pp.30-35, 2010.
DOI : 10.1039/B911763F

D. M. Omiatek, Y. Dong, M. L. Heien, and A. G. Ewing, Only a Fraction of Quantal Content is Released During Exocytosis as Revealed by Electrochemical Cytometry of Secretory Vesicles, ACS Chemical Neuroscience, vol.1, issue.3, pp.234-245, 2010.
DOI : 10.1021/cn900040e

B. Zhang, K. L. Adams, S. J. Luber, D. J. Eves, M. L. Heien et al., Spatially and Temporally Resolved Single-Cell Exocytosis Utilizing Individually Addressable Carbon Microelectrode Arrays, Analytical Chemistry, vol.80, issue.5, pp.1394-1400, 2008.
DOI : 10.1021/ac702409s

Y. Q. Lin, R. Trouillon, M. I. Svensson, J. D. Keighron, A. S. Cans et al., Carbon-Ring Microelectrode Arrays for Electrochemical Imaging of Single Cell Exocytosis: Fabrication and Characterization, Analytical Chemistry, vol.84, issue.6, pp.2949-2954, 2012.
DOI : 10.1021/ac3000368

A. Pasquarelli, V. Carabelli, Y. Xu, E. Colombo, Z. Gao et al., Diamond microelectrodes arrays for the detection of secretory cell activity, International Journal of Environmental Analytical Chemistry, vol.91, issue.2, pp.150-160, 2011.
DOI : 10.1002/pssa.200671122

J. Wang, R. Trouillon, Y. Q. Lin, M. I. Svensson, and A. G. Ewing, Individually Addressable Thin-Film Ultramicroelectrode Array for Spatial Measurements of Single Vesicle Release, Analytical Chemistry, vol.85, issue.11, pp.5600-5608, 2013.
DOI : 10.1021/ac4009385

J. Wang, R. Trouillon, J. Dunevall, and A. G. Ewing, Spatial Resolution of Single-Cell Exocytosis by Microwell-Based Individually Addressable Thin Film Ultramicroelectrode Arrays, Analytical Chemistry, vol.86, issue.9, pp.4515-4520, 2014.
DOI : 10.1021/ac500443q

S. Y. Yang, B. N. Kim, A. A. Zakhidov, P. G. Taylor, J. K. Lee et al., Detection of Transmitter Release from Single Living Cells Using Conducting Polymer Microelectrodes, Advanced Materials, vol.2, issue.24, pp.184-188, 2011.
DOI : 10.1002/adma.201100035

B. X. Shi, Y. Wang, K. Zhang, T. L. Lam, and H. L. Chan, Monitoring of dopamine release in single cell using ultrasensitive ITO microsensors modified with carbon nanotubes, Biosensors and Bioelectronics, vol.26, issue.6, pp.2917-2921, 2011.
DOI : 10.1016/j.bios.2010.11.037

B. Zhang, M. Heien, M. F. Santillo, L. Mellander, and A. G. Ewing, Temporal Resolution in Electrochemical Imaging on Single PC12 Cells Using Amperometry and Voltammetry at Microelectrode Arrays, Analytical Chemistry, vol.83, issue.2, pp.571-577, 2011.
DOI : 10.1021/ac102502g

K. Berberian, K. Kisler, Q. H. Fang, and M. Lindau, Improved Surface-Patterned Platinum Microelectrodes for the Study of Exocytotic Events, Analytical Chemistry, vol.81, issue.21, pp.8734-8740, 2009.
DOI : 10.1021/ac900674g

S. Barizuddin, X. Liu, J. C. Mathai, M. Hossain, K. D. Gillis et al., Automated Targeting of Cells to Electrochemical Electrodes Using a Surface Chemistry Approach for the Measurement of Quantal Exocytosis, ACS Chemical Neuroscience, vol.1, issue.9, pp.590-597, 2010.
DOI : 10.1021/cn1000183

X. Liu, S. Barizuddin, W. Shin, C. J. Mathai, S. Gangopadhyay et al., Microwell Device for Targeting Single Cells to Electrochemical Microelectrodes for High-Throughput Amperometric Detection of Quantal Exocytosis, Analytical Chemistry, vol.83, issue.7, pp.2445-2451, 2011.
DOI : 10.1021/ac1033616

B. N. Kim, A. D. Herbst, S. J. Kim, B. A. Minch, and M. Lindau, Parallel recording of neurotransmitters release from chromaffin cells using a 10??10 CMOS IC potentiostat array with on-chip working electrodes, Biosensors and Bioelectronics, vol.41, pp.736-744, 2013.
DOI : 10.1016/j.bios.2012.09.058

A. Yakushenko, E. Katelhon, and B. Wolfrum, Parallel On-Chip Analysis of Single Vesicle Neurotransmitter Release, Analytical Chemistry, vol.85, issue.11, pp.5483-5490, 2013.
DOI : 10.1021/ac4006183

F. Lemaître, M. Guille-collignon, and C. Amatore, Recent advances in Electrochemical Detection of Exocytosis, Electrochimica Acta, vol.140, pp.457-466, 2014.
DOI : 10.1016/j.electacta.2014.02.059

A. Meunier, R. Fulcrand, F. Darchen, M. Guille-collignon, F. Lemaître et al., Indium Tin Oxide devices for amperometric detection of vesicular release by single cells, Biophysical Chemistry, vol.162, pp.14-21, 2012.
DOI : 10.1016/j.bpc.2011.12.002

K. Kisler, B. N. Kim, X. Liu, K. Berberian, Q. Fang et al., Transparent Electrode Materials for Simultaneous Amperometric Detection of Exocytosis and Fluorescence Microscopy, Journal of Biomaterials and Nanobiotechnology, vol.03, issue.02, pp.243-253, 2012.
DOI : 10.4236/jbnb.2012.322030

X. H. Sun and K. D. Gillis, On-Chip Amperometric Measurement of Quantal Catecholamine Release Using Transparent Indium Tin Oxide Electrodes, Analytical Chemistry, vol.78, issue.8, pp.2521-2525, 2006.
DOI : 10.1021/ac052037d

X. H. Chen, Y. F. Gao, M. Hossain, S. Gangopadhyay, and K. D. Gillis, on transparent indium-tin-oxide microchip electrodes, Lab Chip, vol.28, issue.1, pp.161-169, 2008.
DOI : 10.1039/B715308M

V. Carabelli, S. Gosso, A. Marcantoni, Y. Xu, E. Colombo et al., Nanocrystalline diamond microelectrode arrays fabricated on sapphire technology for high-time resolution of quantal catecholamine secretion from chromaffin cells, Biosensors and Bioelectronics, vol.26, issue.1, pp.92-98, 2010.
DOI : 10.1016/j.bios.2010.05.017