O. Simonetti, J. Finn, R. White, G. Laub, and D. Henry, "Black blood" T2-weighted inversion-recovery MR imaging of the heart., Radiology, vol.199, issue.1, pp.49-57, 1996.
DOI : 10.1148/radiology.199.1.8633172

C. Broberg, S. Chugh, C. Conklin, D. Sahn, and M. Jerosch-herold, Quantification of Diffuse Myocardial Fibrosis and Its Association With Myocardial Dysfunction in Congenital Heart Disease, Circulation: Cardiovascular Imaging, vol.3, issue.6, pp.727-734, 2010.
DOI : 10.1161/CIRCIMAGING.108.842096

J. Vogel-claussen, C. Rochitte, K. Wu, I. Kamel, T. Foo et al., Delayed enhancement MR imaging: utility in myocardial assessment. Radiographics: a review publication of the, Inc, vol.26, pp.795-810

N. Ghugre, C. Enriquez, I. Gonzalez, M. Nelson, T. Coates et al., MRI detects myocardial iron in the human heart, Magnetic Resonance in Medicine, vol.16, issue.3, pp.681-686, 2006.
DOI : 10.1002/mrm.20981

M. Salerno and C. Kramer, Advances in Parametric Mapping With CMR Imaging, JACC: Cardiovascular Imaging, vol.6, issue.7, pp.806-822, 2013.
DOI : 10.1016/j.jcmg.2013.05.005

L. Iles, H. Pfluger, A. Phrommintikul, J. Cherayath, P. Aksit et al., Evaluation of diffuse myocardial fibrosis in heart failure with cardiac magnetic resonance contrast-enhanced T1 mapping, Journal of the American College of Cardiology, vol.52, 2008.

H. Arheden, M. Saeed, C. Higgins, D. Gao, J. Bremerich et al., Tc-DTPA Autoradiography in Rats, Radiology, vol.211, issue.3, pp.698-708, 1999.
DOI : 10.1148/radiology.211.3.r99jn41698

D. Messroghli, A. Radjenovic, S. Kozerke, D. Higgins, M. Sivananthan et al., Modified Look-Locker inversion recovery (MOLLI) for high-resolutionT1 mapping of the heart, Magnetic Resonance in Medicine, vol.97, issue.1, pp.141-146, 2004.
DOI : 10.1002/mrm.20110

C. Sibley, R. Noureldin, N. Gai, M. Nacif, E. Turkbey et al., T1 Mapping in Cardiomyopathy at Cardiac MR: Comparison with Endomyocardial Biopsy, Radiology, vol.265, issue.3, pp.724-732, 2012.
DOI : 10.1148/radiol.12112721

J. Brooks, C. Kramer, and M. Salerno, mapping, Journal of Magnetic Resonance Imaging, vol.6, issue.Suppl 1, pp.1591-1595, 2013.
DOI : 10.1002/jmri.24078

E. Dall-'armellina, S. Piechnik, V. Ferreira, Q. Si, . Le et al., Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarction, Journal of Cardiovascular Magnetic Resonance, vol.14, issue.1, pp.15-25, 2012.
DOI : 10.1186/1532-429X-11-56

V. Ferreira, S. Piechnik, E. Dall-'armellina, T. Karamitsos, J. Francis et al., Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance, Journal of Cardiovascular Magnetic Resonance, vol.14, issue.1, pp.42-52, 2012.
DOI : 10.1016/j.jacc.2008.06.049

D. Sado, S. White, S. Piechnik, S. Banypersad, T. Treibel et al., Identification and Assessment of Anderson-Fabry Disease by Cardiovascular Magnetic Resonance Noncontrast Myocardial T1 Mapping, Circulation: Cardiovascular Imaging, vol.6, issue.3, pp.392-398, 2013.
DOI : 10.1161/CIRCIMAGING.112.000070

J. Lee, S. Liu, M. Nacif, M. Ugander, J. Han et al., Myocardial T1 and extracellular volume fraction mapping at 3 tesla, Journal of Cardiovascular Magnetic Resonance, vol.13, issue.1, pp.75-85, 2011.
DOI : 10.1111/j.1748-1716.1946.tb00325.x

N. Gai, C. Stehning, M. Nacif, and D. Bluemke, Modified Look-Locker T1 evaluation using Bloch simulations: Human and phantom validation, Magnetic Resonance in Medicine, vol.67, 2012.

R. Deichmann and A. Haase, Quantification of T1 values by SNAPSHOT-FLASH NMR imaging, Journal of Magnetic Resonance (1969), vol.96, issue.3, pp.608-612, 1992.
DOI : 10.1016/0022-2364(92)90347-A

B. Hargreaves, S. Vasanawala, J. Pauly, and D. Nishimura, Characterization and reduction of the transient response in steady-state MR imaging, Magnetic Resonance in Medicine, vol.4, issue.1, pp.149-158, 2001.
DOI : 10.1002/mrm.1170

P. Kellman, D. Herzka, and M. Hansen, Adiabatic inversion pulses for myocardial T1 mapping, Magnetic Resonance in Medicine, vol.70, issue.Suppl 1, pp.1428-1434, 2014.
DOI : 10.1002/mrm.24793

J. Nelder and R. Mead, A Simplex Method for Function Minimization, The Computer Journal, vol.7, issue.4, pp.308-313, 1965.
DOI : 10.1093/comjnl/7.4.308

S. Giri, Y. Chung, A. Merchant, G. Mihai, S. Rajagopalan et al., T2 quantification for improved detection of myocardial edema, Journal of Cardiovascular Magnetic Resonance, vol.11, issue.1, 2009.
DOI : 10.1186/1532-429X-11-56

L. Sacolick, F. Wiesinger, I. Hancu, and M. Vogel, B1 mapping by Bloch-Siegert shift, Magnetic Resonance in Medicine, vol.53, issue.5, pp.1315-1322, 2010.
DOI : 10.1002/mrm.22357

S. Ourselin, A. Roche, A. Prima, and N. Ayache, Medical Image Computing and Computer-Assisted Intervention?MICCAI, Lecture Notes in Computer Science, 1935.
URL : https://hal.archives-ouvertes.fr/inria-00616017

V. Knobelsdorff-brenkenhoff, F. Prothmann, M. Dieringer, M. Wassmuth, R. Greiser et al., Myocardial T1 and T2 mapping at 3??T: reference values, influencing factors and implications, Journal of Cardiovascular Magnetic Resonance, vol.15, issue.1, pp.53-63, 2013.
DOI : 10.1002/mrm.24385

C. Cunningham, J. Pauly, and K. Nayak, Saturated double-angle method for rapidB1+ mapping, Magnetic Resonance in Medicine, vol.51, issue.6, pp.1326-1333, 2006.
DOI : 10.1002/mrm.20896

E. Insko and L. Bolinger, Mapping of the Radiofrequency Field, Journal of Magnetic Resonance, Series A, vol.103, issue.1, pp.82-85, 1993.
DOI : 10.1006/jmra.1993.1133

R. Stollberger and P. Wach, Imaging of the activeB1 fieldin vivo, Magnetic Resonance in Medicine, vol.8, issue.2, pp.246-251, 1996.
DOI : 10.1002/mrm.1910350217

V. Yarnykh, Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field, Magnetic Resonance in Medicine, vol.55, issue.1, pp.192-200, 2007.
DOI : 10.1002/mrm.21120

N. Dowell and P. Tofts, Fast, accurate, and precise mapping of the RF field in vivo using the 180?? signal null, Magnetic Resonance in Medicine, vol.33, issue.3, pp.622-630, 2007.
DOI : 10.1002/mrm.21368

F. Jiru and U. Klose, Fast 3D radiofrequency field mapping using echo-planar imaging, Magnetic Resonance in Medicine, vol.50, issue.6, pp.1375-1379, 2006.
DOI : 10.1002/mrm.21083

W. Dixon, L. Sacolick, F. Wiesinger, M. Vogel, and I. Hancu, Flow, Chemical Shift, and Phase-based B1 Mapping, Proc. ISMRM, 2010.

A. Lau, A. Chen, and C. Cunningham, Integrated Bloch-Siegert B1 mapping and multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart, Magnetic Resonance in Medicine, vol.60, issue.1, pp.62-71, 2012.
DOI : 10.1002/mrm.22977

S. Piechnik, V. Ferreira, E. Dall-'armellina, L. Cochlin, A. Greiser et al., Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold, Journal of Cardiovascular Magnetic Resonance, vol.12, issue.1, pp.69-79, 2010.
DOI : 10.1186/1532-429X-12-69

K. Chow, J. Flewitt, J. Green, J. Pagano, M. Friedrich et al., Saturation recovery single-shot acquisition (SASHA) for myocardial T(1) mapping. Magnetic resonance in medicine 71, pp.2082-2095, 2014.

M. Robson, S. Piechnik, E. Tunnicliffe, and S. Neubauer, T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences. Magnetic resonance in medicine, 2013.

P. Kellman and M. Hansen, T1-mapping in the heart: accuracy and precision, Journal of Cardiovascular Magnetic Resonance, vol.16, issue.1, p.24387626, 2014.
DOI : 10.1186/1532-429X-14-26

G. Stanisz, E. Odrobina, J. Pun, M. Escaravage, S. Graham et al., T1, T2 relaxation and magnetization transfer in tissue at 3T, Magnetic Resonance in Medicine, vol.21, issue.3, pp.507-512, 2005.
DOI : 10.1002/mrm.20605

H. Clique, H. Cheng, P. Marie, J. Felblinger, and M. Beaumont, ) mapping at 3T using variable flip angle method: Pilot study, Magnetic Resonance in Medicine, vol.31, issue.829, pp.823-829, 2013.

R. Van-heeswijk, H. Feliciano, C. Bongard, G. Bonanno, S. Coppo et al., Free-Breathing 3 T Magnetic Resonance T2-Mapping of the Heart, JACC: Cardiovascular Imaging, vol.5, issue.12, pp.1231-1239, 2012.
DOI : 10.1016/j.jcmg.2012.06.010

M. Robson, S. Piechnik, E. Tunnicliffe, and S. Neubauer, T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences, Magnetic Resonance in Medicine, 2013.

P. Kellman, D. Herzka, A. Arai, and M. Hansen, Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method, Journal of Cardiovascular Magnetic Resonance, vol.15, issue.1, pp.63-23875774, 2013.
DOI : 10.1186/1532-429X-15-56