E. J. Schantz, W. G. Roessler, M. J. Woodburn, J. M. Lynch, H. M. Jacoby et al., Purification and some chemical and physical properties of staphylococcal enterotoxin A, Biochemistry, vol.11, issue.3, pp.11-360, 1972.
DOI : 10.1021/bi00753a009

M. Sharma, Lytic bacteriophages, Bacteriophage, vol.71, issue.2, 2013.
DOI : 10.1128/AEM.69.8.4519-4526.2003

URL : http://www.tandfonline.com/doi/pdf/10.4161/bact.25518?needAccess=true

P. Arora, A. Sindhu, N. Dilbaghi, and A. Chaudhury, Biosensors as innovative tools for the detection of food borne pathogens, Biosensors and Bioelectronics, vol.28, issue.1, pp.1-12, 2011.
DOI : 10.1016/j.bios.2011.06.002

J. Homola, J. Dostálek, S. Chen, A. Rasooly, S. Jiang et al., Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk, International Journal of Food Microbiology, vol.75, issue.1-2, pp.75-61, 2002.
DOI : 10.1016/S0168-1605(02)00010-7

W. Lian, D. Wu, D. V. Lim, and S. Jin, Sensitive detection of multiplex toxins using antibody microarray, Analytical Biochemistry, vol.401, issue.2, pp.271-280, 2010.
DOI : 10.1016/j.ab.2010.02.040

M. B. Medina, A BIOSENSOR METHOD FOR A COMPETITIVE IMMUNOASSAY DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN B (SEB) IN MILK2, Journal of Rapid Methods and Automation in Microbiology, vol.50, issue.1, pp.37-55, 2005.
DOI : 10.1016/S0378-1097(98)00423-6

M. B. Medina, A BIOSENSOR METHOD FOR DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN A IN RAW WHOLE EGG*, Journal of Rapid Methods and Automation in Microbiology, vol.168, issue.4, pp.119-151, 2006.
DOI : 10.1016/S0168-1605(00)00416-5

A. N. Naimushin, S. D. Soelberg, D. K. Nguyen, L. Dunlap, D. Bartholomew et al., Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor, Biosensors and Bioelectronics, vol.17, issue.6-7, pp.17-573, 2002.
DOI : 10.1016/S0956-5663(02)00014-3

L. Rasooly and A. Rasooly, Real time biosensor analysis of Staphylococcal enterotoxin A in food, International Journal of Food Microbiology, vol.49, issue.3, pp.49-119, 1999.
DOI : 10.1016/S0168-1605(99)00053-7

W. Tsai and I. Li, SPR-based immunosensor for determining staphylococcal enterotoxin A, Sensors and Actuators B: Chemical, vol.136, issue.1, pp.8-12, 2009.
DOI : 10.1016/j.snb.2008.10.061

W. Tsai and P. R. Pai, Surface plasmon resonance-based immunosensor with oriented immobilized antibody fragments on a mixed self-assembled monolayer for the determination of staphylococcal enterotoxin B, Microchimica Acta, vol.69, issue.1-2, pp.166-115, 2009.
DOI : 10.1007/s00604-009-0171-1

J. B. Delehanty and F. S. Ligler, A Microarray Immunoassay for Simultaneous Detection of Proteins and Bacteria, Analytical Chemistry, vol.74, issue.21, pp.74-5681, 2002.
DOI : 10.1021/ac025631l

M. E. Pekdemir, D. Erturkan, H. Kulah, I. H. Boyac, C. Ozgen et al., Ultrasensitive and selective homogeneous sandwich immunoassay detection by Surface Enhanced Raman Scattering (SERS), The Analyst, vol.85, issue.5, pp.137-4834, 2012.
DOI : 10.1007/s00253-009-2347-3

E. Temur, A. Zengin, I. H. Boyaci, F. C. Dudak, H. Torul et al., Attomole Sensitivity of Staphylococcal Enterotoxin B Detection Using an Aptamer-Modified Surface-Enhanced Raman Scattering Probe, Analytical Chemistry, vol.84, issue.24, pp.10600-10606, 2012.
DOI : 10.1021/ac301924f

X. Yang, X. Zhao, X. Zuo, K. Wang, J. Wen et al., Nucleic acids detection using cationic fluorescent polymer based on one-dimensional microfluidic beads array, Talanta, vol.77, issue.3, pp.77-1027, 2009.
DOI : 10.1016/j.talanta.2008.08.001

G. A. Campbell, M. B. Medina, and R. Mutharasan, Detection of Staphylococcus enterotoxin B at picogram levels using piezoelectric-excited millimeter-sized cantilever sensors, Sensors and Actuators B: Chemical, vol.126, issue.2, pp.126-354, 2007.
DOI : 10.1016/j.snb.2007.03.021

Z. Gao, F. Chao, Z. Chao, and G. Li, Detection of staphylococcal enterotoxin C2 employing a piezoelectric crystal immunosensor, Sensors and Actuators B: Chemical, vol.66, issue.1-3, pp.66-193, 2000.
DOI : 10.1016/S0925-4005(00)00377-4

J. L. Harteveld, M. S. Nieuwenhuizen, and E. R. Wils, Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor, Biosensors and Bioelectronics, vol.12, issue.7, pp.12-661, 1997.
DOI : 10.1016/S0956-5663(97)00024-9

N. Karaseva and T. Ermolaeva, A regenerable piezoelectric immunosensor on the basis of electropolymerized polypyrrole for highly selective detection of Staphylococcal Enterotoxin A in foodstuffs, Microchimica Acta, vol.197, issue.4, pp.1329-1364, 2015.
DOI : 10.1016/j.snb.2014.02.072

. Alves, Development of an amperometric immunosensor for detection of staphylococcal enterotoxin type A in cheese, J Microbiol Methods, pp.91-138, 2012.

M. S. Desilva, Y. Zhang, P. J. Hesketh, G. J. Maclay, S. M. Gendel et al., Impedance based sensing of the specific binding reaction between Staphylococcus enterotoxin B and its antibody on an ultra-thin platinum film, Biosensors and Bioelectronics, vol.10, issue.8, pp.10-675, 1995.
DOI : 10.1016/0956-5663(95)96958-2

W. Jin, K. Yamada, M. Ikami, N. Kaji, M. Tokeshi et al., Application of IgY to sandwich enzyme-linked immunosorbent assays, lateral flow devices, and immunopillar chips for detecting staphylococcal enterotoxins in milk and dairy products, Journal of Microbiological Methods, vol.92, issue.3, pp.92-323, 2013.
DOI : 10.1016/j.mimet.2013.01.001

T. Kasama, M. Ikami, W. Jin, K. Yamada, N. Kaji et al., Rapid, highly sensitive, and simultaneous detection of staphylococcal enterotoxins in milk by using immuno-pillar devices, Anal. Methods, vol.130, issue.12, pp.5092-5097, 2015.
DOI : 10.1017/S0950268802007951

P. Skládal, Piezoelectric biosensors, TrAC Trends in Analytical Chemistry, vol.79, pp.127-160, 2016.
DOI : 10.1016/j.trac.2015.12.009

L. Reverté, B. Prieto-simón, and M. Campàs, New advances in electrochemical biosensors for the detection of toxins: Nanomaterials, magnetic beads and microfluidics systems. A??review, Analytica Chimica Acta, vol.908, pp.908-916, 2016.
DOI : 10.1016/j.aca.2015.11.050

B. , S. Inbaraj, and B. H. Chen, Nanomaterial-based sensors for detection of foodborne bacterial pathogens and toxins as well as pork adulteration in meat products, J Food Drug Anal, pp.24-39, 2016.

J. Breault-turcot and J. F. Masson, Nanostructured substrates for portable and miniature SPR biosensors, Analytical and Bioanalytical Chemistry, vol.37, issue.5, pp.403-1477, 2012.
DOI : 10.1039/b708461g

Y. Li, H. Schluesener, and S. Xu, Gold nanoparticle-based biosensors, Gold Bulletin, vol.332, issue.1, pp.29-41, 2010.
DOI : 10.1016/j.jim.2007.12.019

URL : https://link.springer.com/content/pdf/10.1007%2FBF03214964.pdf

X. Cao, Y. Ye, and S. Liu, Gold nanoparticle-based signal amplification for biosensing, Analytical Biochemistry, vol.417, issue.1, pp.417-418, 2011.
DOI : 10.1016/j.ab.2011.05.027

A. Morel, S. Boujday, C. Méthivier, J. Krafft, and C. Pradier, Biosensors elaborated on gold nanoparticles, a PM-IRRAS characterisation of the IgG binding efficiency, Talanta, vol.85, issue.1, pp.85-120, 2011.
DOI : 10.1016/j.talanta.2011.02.028

URL : https://hal.archives-ouvertes.fr/hal-00668945

A. Morel, R. Volmant, C. Méthivier, J. Krafft, S. Boujday et al., Optimized immobilization of gold nanoparticles on planar surfaces through alkyldithiols and their use to build 3D biosensors, Colloids and Surfaces B: Biointerfaces, vol.81, issue.1, pp.81-304, 2010.
DOI : 10.1016/j.colsurfb.2010.07.021

URL : https://hal.archives-ouvertes.fr/hal-00604782

P. Chu, C. Lin, W. Chen, C. Chen, and H. Wen, Detection of Gliadin in Foods Using a Quartz Crystal Microbalance Biosensor That Incorporates Gold Nanoparticles, Journal of Agricultural and Food Chemistry, vol.60, issue.26, pp.60-6483, 2012.
DOI : 10.1021/jf2047866

R. A. Fonseca, J. Ramos-jesus, L. T. Kubota, and R. F. Dutra, A Nanostructured Piezoelectric Immunosensor for Detection of Human Cardiac Troponin T, Sensors, vol.603, issue.12, pp.11-10785, 2011.
DOI : 10.1016/j.jelechem.2007.02.004

A. Makaraviciute, T. Ruzgas, A. Ramanavicius, and A. Ramanaviciene, A QCM-D Study of Reduced Antibody Fragments Immobilized on Planar Gold and Gold Nanoparticle Modified Sensor Surfaces, Key Engineering Materials, vol.605, pp.605-340, 2014.
DOI : 10.4028/www.scientific.net/KEM.605.340

H. Chen, J. Jiang, Y. Huang, T. Deng, J. Li et al., An electrochemical impedance immunosensor with signal amplification based on Au-colloid labeled antibody complex, Sensors and Actuators B: Chemical, vol.117, issue.1, pp.117-211, 2006.
DOI : 10.1016/j.snb.2005.11.026

D. Tang, D. Zhang, D. Tang, and H. Ai, Amplification of the antigen???antibody interaction from quartz crystal microbalance immunosensors via back-filling immobilization of nanogold on biorecognition surface, Journal of Immunological Methods, vol.316, issue.1-2, pp.316-144, 2006.
DOI : 10.1016/j.jim.2006.08.012

H. Wang, C. Lei, J. Li, Z. Wu, G. Shen et al., A piezoelectric immunoagglutination assay for Toxoplasma gondii antibodies using gold nanoparticles, Biosensors and Bioelectronics, vol.19, issue.7, pp.701-710, 2004.
DOI : 10.1016/S0956-5663(03)00265-3

H. Wang, J. Wu, J. Li, Y. Ding, G. Shen et al., Nanogold particle-enhanced oriented adsorption of antibody fragments for immunosensing platforms, Biosensors and Bioelectronics, vol.20, issue.11, pp.20-2210, 2005.
DOI : 10.1016/j.bios.2004.07.024

A. Papadopoulou-bouraou, J. Barrero-moreno, M. Lejeune, F. Brétagnol, M. Manso et al., Plasma-Polymerized Allylamine-Based Label-Free Piezoelectric Immunosensor Platform: Characterization and Application, pp.18-353, 2006.

X. Jia, Q. Xie, Y. Zhang, and S. Yao, Simultaneous Quartz Crystal Microbalance-Electrochemical Impedance Spectroscopy Study on the Adsorption of Anti-human Immunoglobulin G and Its Immunoreaction at Nanomaterial-modified Au Electrode Surfaces, Analytical Sciences, vol.23, issue.6, pp.689-96, 2007.
DOI : 10.2116/analsci.23.689

X. Chu, Z. Zhao, G. Shen, and R. Yu, Quartz crystal microbalance immunoassay with dendritic amplification using colloidal gold immunocomplex, Sensors and Actuators B: Chemical, vol.114, issue.2, pp.114-696, 2006.
DOI : 10.1016/j.snb.2005.06.014

Y. Ding, Y. Y. Zhou, H. Chen, D. D. Geng, D. Y. Wu et al., The performance of thiol-terminated PEG-paclitaxel-conjugated gold nanoparticles, Biomaterials, vol.34, issue.38, pp.34-10217, 2013.
DOI : 10.1016/j.biomaterials.2013.09.008

X. Jin, X. Jin, L. Chen, J. Jiang, G. Shen et al., Piezoelectric immunosensor with gold nanoparticles enhanced competitive immunoreaction technique for quantification of aflatoxin B1, Biosensors and Bioelectronics, vol.24, issue.8, pp.24-2580, 2009.
DOI : 10.1016/j.bios.2009.01.014

N. H. Kim, T. J. Baek, H. G. Park, and G. H. Seong, Highly Sensitive Biomolecule Detection on a Quartz Crystal Microbalance Using Gold Nanoparticles as Signal Amplification Probes, Analytical Sciences, vol.23, issue.2, pp.177-81, 2007.
DOI : 10.2116/analsci.23.177

S. B. Reddy, D. E. Mainwaring, M. Kobaisi, P. Zeephongsekul, and J. V. Fecondo, Acoustic wave immunosensing of a meningococcal antigen using gold nanoparticle-enhanced mass sensitivity, Biosensors and Bioelectronics, vol.31, issue.1, pp.31-382, 2012.
DOI : 10.1016/j.bios.2011.10.051

J. Han, J. Zhang, Y. Xia, and L. Jiang, Highly sensitive detection of the hepatotoxin microcystin-LR by surface modification and bio-nanotechnology, Colloids and Surfaces A: Physicochemical and Engineering Aspects, vol.391, issue.1-3, pp.391-184, 2011.
DOI : 10.1016/j.colsurfa.2011.01.043

M. B. Haddada, J. Blanchard, S. Casale, J. Krafft, A. Vallée et al., Optimizing the immobilization of gold nanoparticles on functionalized silicon surfaces: amine-vs thiol-terminated silane, Gold Bull, pp.46-335, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00982928

L. Dalstein, M. B. Haddada, G. Barbillon, C. Humbert, A. Tadjeddine et al., Revealing the Interplay between Adsorbed Molecular Layers and Gold Nanoparticles by Linear and Nonlinear Optical Properties, The Journal of Physical Chemistry C, vol.119, issue.30, pp.119-17146, 2015.
DOI : 10.1021/acs.jpcc.5b03601

J. W. Slot and H. J. Geuze, A method to prepare isodisperse colloidal gold sols in the size range 3???17 NM, Ultramicroscopy, vol.15, issue.4, p.15, 1984.
DOI : 10.1016/0304-3991(84)90144-X

S. Boujday, S. Nasri, M. Salmain, and C. M. Pradier, Surface IR immunosensors for label-free detection of benzo[a]pyrene, Biosensors and Bioelectronics, vol.26, issue.4, pp.1750-1754, 2010.
DOI : 10.1016/j.bios.2010.08.031

URL : https://hal.archives-ouvertes.fr/hal-00604705

D. Mercier, S. Boujday, C. Annabi, R. Villanneau, C. Pradier et al., Bifunctional Polyoxometalates for Planar Gold Surface Nanostructuration and Protein Immobilization, The Journal of Physical Chemistry C, vol.116, issue.24, pp.116-13217, 2012.
DOI : 10.1021/jp3031623

URL : https://hal.archives-ouvertes.fr/hal-00748285

M. Salmain, M. Ghasemi, S. Boujday, J. Spadavecchia, C. Técher et al., Piezoelectric immunosensor for direct and rapid detection of staphylococcal enterotoxin A (SEA) at the ng level, Biosensors and Bioelectronics, vol.29, issue.1, pp.29-140, 2011.
DOI : 10.1016/j.bios.2011.08.007

S. Boujday, A. Bantegnie, E. Briand, P. Marnet, M. Salmain et al., In-Depth Investigation of Protein Adsorption on Gold Surfaces: Correlating the Structure and Density to the Efficiency of the Sensing Layer, Depth Investigation of Protein Adsorption on Gold Surfaces: Correlating the Structure and Density to the Efficiency of the Sensing Layer, pp.6708-6723, 2008.
DOI : 10.1021/jp711916g

URL : https://hal.archives-ouvertes.fr/hal-00729928

M. Salmain, M. Ghasemi, S. Boujday, and C. Pradier, Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance, Sensors and Actuators B: Chemical, vol.173, pp.173-148, 2012.
DOI : 10.1016/j.snb.2012.06.052

URL : https://hal.archives-ouvertes.fr/hal-00744497