Experimental study of magnetoelectric transducers for power supply of small biomedical devices

Abstract : This paper presents experiment results of an energy transducer based on the magnetoelectric composites. Various configurations of the layered structure composed of the Terfenol-D or/and the Metglas with the PZT-5H have been investigated. The impact of Metglas on the performance of the transducer is outlined. The high output voltage coefficient and the significant deliverable power of the combination Terfenol-D/Metglas/PZT-5H makes it as an ideal energy transducer candidate for wireless powering of embedded device in biomedical applications.
Document type :
Journal articles
Complete list of metadatas

https://hal.sorbonne-universite.fr/hal-01710270
Contributor : Pascal Gomez <>
Submitted on : Thursday, February 15, 2018 - 5:23:44 PM
Last modification on : Monday, March 23, 2020 - 4:46:03 PM

Identifiers

Citation

Kevin Malleron, Aurélie Gensbittel, Hakeim Talleb, Zhuoxiang Ren. Experimental study of magnetoelectric transducers for power supply of small biomedical devices. Microelectronics Journal, Elsevier, 2018, in press. ⟨10.1016/j.mejo.2018.01.013⟩. ⟨hal-01710270⟩

Share

Metrics

Record views

352